June 2, 2025 — Meeting Minutes

This document is the minutes of the City Plan Commission/Architectural Review Board meeting held June 2, 2025. It records attendance, approval of the May 5, 2025 minutes, and deliberations on several applications including accessory structures, new single‑family homes, fencing, and residential additions. The excerpts show staff recommendations and that the board voted unanimously to approve several items (63 Arundel Place; 7474 York Drive with a 4‑foot front fence height condition; 46 Hillvale Drive), recommended approval of a conditional use permit to the Board of Aldermen for 515 South Central Avenue with a dry‑well recording requirement, and continued the 8141 Pershing Avenue application to a later date; it also includes a presentation on proposed commercial zoning regulation changes.
Cited passage
3. The applicant shall contribute to the city forestry fund compensatory with the requirements of Section

405.4110.C.2.A. David Chan, Owner, and Tony Camacho, Architect/Applicant were present on behalf of the project. PC-ARB discussed the project with the project representatives. Bob Denlow made a motion to approve with the following conditions:

report must assess the performance of the proposed drywell based on the anticipated impact of a 15-year, 20- minute storm event. Should the results indicate that the proposed drywell is insufficient to accommodate the stormwater runoff generated by this event, the applicant shall be required to upsize the drywell accordingly to ensure adequate performance and compliance with applicable stormwater management standards.

restriction noting the location and maintenance requirements of the dry-well system and shall submit proof of the recording prior to issuance of a Building Permit.

report must assess the performance of the proposed drywell based on the anticipated impact of a 15-year, 20- minute storm event. Should the results indicate that the proposed drywell is insufficient to accommodate the stormwater runoff generated by this event, the applicant shall be required to upsize the drywell accordingly to ensure adequate performance and compliance with applicable stormwater management standards.

restriction noting the location and maintenance requirements of the dry-well system and shall submit proof of the recording prior to issuance of a Building Permit.